Last Modified: 11-29-2007 |
1.6 C |
|
Service Category: Drivetrain |
Section: Automatic Transmission/Transaxle |
|
Model Year: 2008 |
Model: Sequoia |
Doc ID: RM000000W8A056X |
|
Title: A750E AUTOMATIC TRANSMISSION / TRANSAXLE: AUTOMATIC TRANSMISSION SYSTEM: DESCRIPTION (2008 Sequoia) |
|
DTC
|
P2716
|
Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)
|
DESCRIPTION
Refer to DTC P0894
.
|
DTC No.
|
DTC Detection Condition
|
Trouble Area
|
|
P2716
|
Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic).
|
-
Open or short in shift solenoid valve SLT circuit
-
Shift solenoid valve SLT
-
ECM
|
MONITOR DESCRIPTION
When an open or short in the shift solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.
MONITOR STRATEGY
|
Related DTCs
|
P2716: Shift solenoid valve SLT/Range check
|
|
Required sensors/Components
|
Shift solenoid valve SLT
|
|
Frequency of operation
|
Continuous
|
|
Duration
|
1 second
|
|
MIL operation
|
Immediately
|
|
Sequence of operation
|
None
|
TYPICAL ENABLING CONDITIONS
All
|
The monitor will run whenever the following DTCs are not present
|
None
|
All of the following conditions are met: Condition (A) and (B)
Condition (A)
|
Solenoid current cut status
|
Not cut
|
|
Battery voltage
|
11 V or more
|
|
Ignition switch
|
ON
|
|
Starter
|
OFF
|
Condition (B)
|
Battery voltage
|
8 V or more
|
|
Ignition switch
|
ON
|
|
Starter
|
OFF
|
TYPICAL MALFUNCTION THRESHOLDS
When either condition below is met: Condition (A) or (B)
Condition (A)
|
Solenoid status from hybrid IC
|
Failure (open or short)
|
Condition (B)
COMPONENT OPERATING RANGE
|
Output signal duty
|
Less than 100%
|
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
|
1.
|
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)
|
|
(a) Disconnect the D41 transmission wire connector.
|
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
14 (SLT+) - 6 (SLT-)
|
20°C (68°F)
|
5.0 to 5.6 Ω
|
|
14 (SLT+) - Body ground
|
Always
|
10 kΩ or higher
|
|
6 (SLT-) - Body ground
|
Always
|
10 kΩ or higher
|
| OK |
|
|
|
2.
|
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
|
|
(a) Disconnect the D56 ECM connector.
|
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
D56-9 (SLT+) - D56-8 (SLT-)
|
20°C (68°F)
|
5.0 to 5.6 Ω
|
|
D56-9 (SLT+) - Body ground
|
Always
|
10 kΩ or higher
|
|
D56-8 (SLT-) - Body ground
|
Always
|
10 kΩ or higher
|
| OK |
|
|
|
3.
|
INSPECT SHIFT SOLENOID VALVE SLT
|
|
(a) Remove the shift solenoid valve SLT.
|
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
1 - 2
|
20°C (68°F)
|
5.0 to 5.6 Ω
|
(c) Connect the battery positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
OK:
Valve moves and makes an operating noise.
| OK |
|
|
|